Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
Res. Biomed. Eng. (Online) ; 32(1): 28-34, Jan.-Mar. 2016. tab, graf
Article in English | LILACS | ID: biblio-829459

ABSTRACT

Abstract Introduction The method of graft fixation is critical in anterior cruciate ligament (ACL) reconstruction surgery. Success of surgery is totally dependent on the ability of the implant to secure the graft inside the bone tunnel until complete graft integration. The principle of EndoButton is based on the cortical suspension of the graft. The Cross-Pin is based on graft expansion. The aim of this study was to evaluate the biomechanical performance of EndoButton and Bio Cross-Pin to fix the hamstring graft at femoral side of porcine knee joints and evaluate whether they are able to support of loading applied on graft during immediate post-operative tasks. Methods Fourteen ACL reconstructions were carried out in porcine femurs fixing superficial flexor tendons with Titanium EndoButton (n = 7) and with 6 × 50 mm HA/PLLA Bio Cross-Pin (n = 7). A cyclic loading test was applied with 50-250 N of tensile force at 1 Hz for 1000 cycles. The displacement was measured at 20, 100, 500 and 1000 load cycles to quantify the slippage of the graft during the test. Single-cycle load-to-failure test was performed at 50 N/mm to measure fixation strength. Results The laxity during cyclic loading and the displacement to failure during single-cycle test were lower for the Bio Cross-Pin fixation (8.21 ± 1.72 mm) than the EndoButton (11.20 ± 2.00 mm). The Bio Cross-Pin (112.22 ± 21.20 N.mm–1) was significantly stiffer than the EndoButton fixation (60.50 ±10.38 N.mm–1). There was no significant difference between Bio Cross-Pin (failure loading: 758.29 ± 188.05 N; yield loading: 713.67 ± 192.56 N) and EndoButton strength (failure loading: 672.52 ± 66.56 N; yield loading: 599.91 ± 59.64 N). Both are able to support the immediate post-operative loading applied (445 N). Conclusion The results obtained in this experiment indicate that the Bio Cross-Pin technique promote stiffer fixation during cyclic loading as compared with EndoButton. Both techniques are able to support the immediate post-operative loading applied.

2.
Res. Biomed. Eng. (Online) ; 31(1): 56-61, Jan-Mar/2015. tab, graf
Article in English | LILACS | ID: biblio-829416

ABSTRACT

Introduction The rupture of the anterior cruciate ligament (ACL) is the most common type of knee injury. Reconstructive surgery is the ‘gold standard’ treatment. During the immediate post-operative period, the fixation of the graft is entirely dependent on the ability of the grafted implant to be secured inside the bone tunnel under the cyclical loads associated with daily tasks. Poor fixation can lead to graft slippage, thus impairing the healing and integration of the graft. The aim of this study was to evaluate the biomechanical performance of tendon graft fixation devices with metallic and bioabsorbable interference screws. Methods Twenty ACL reconstructions were carried out in porcine tibias using deep flexor tendons to fix 9 × 20 mm metallic (n=10) and PLLA 70/30 bioabsorbable screws (n=10). To verify the ability of a construct to resist immediate postoperative (PO) rehabilitation protocols for immediate load bearing, a cyclic loading test was applied with 50-250 N of tensile force at 1 Hz for 1000 cycles, and the displacement was measured at 10, 50, 100, 500 and 1000 load cycles to quantify the slippage of the graft during the test. After the cyclic loading test, a single-cycle load-to-failure test was applied. Results The slippage of the graft using metallic screws did not differ (P = 0.616) from that observed when using bioabsorbable screws. Conclusion The results obtained in this experiment indicate that metallic screws may promote a similar amount of graft slippage during low cyclic loading as bioabsorbable screws. Additionally, there was no difference in the biomechanical performance of these two types of screws during high failure loads.

3.
Acta ortop. bras ; 17(2): 18-23, 2009. ilus, graf, tab
Article in Portuguese | LILACS | ID: lil-515942

ABSTRACT

OBJETIVO: Por ser a articulação mecanicamente mais solicitada de nossa estrutura e pelo grande número de lesões associadas, motivaram a construção de um modelo tridimensional da articulação do joelho humano para simular a cinemática da articulação e obter as solicitações mecânicas nos principais ligamentos durante o movimento de flexão do joelho. Essas informações podem futuramente ser empregada como ferramenta de apoio à decisão médica em ortopedia, fornecendo subsídios na escolha do procedimento cirúrgico. MÉTODOS: Método dos Elementos Finitos foi utilizado para construir um modelo biomecânico, tridimensional, da articulação do joelho. Nesse modelo com seis graus de liberdade é aplicado movimento de flexão/extensão sendo os demais cinco graus de liberdade governados pelas interações entre os componentes da articulares. RESULTADOS: Foram obtidas informações dos movimentos, das rotações interna/externa e adução/abdução, das translações anterior/posterior, lateral/medial e superior/inferior e dos esforços nos quatro principais ligamentos articulares, no decorrer de um amplo movimento de flexão/extensão. Estes valores foram comparados, de forma qualitativa, com valores equivalentes obtidos na literatura. CONCLUSÃO: A análise de resultados permitiu observar que vários aspectos cinemáticos são satisfatoriamente reproduzidos. A pré-carga inicial dos ligamentos e o posicionamento das inserções ligamentares no modelo mostraram-se variáveis relevantes nos resultados.


OBJECTIVE: The knee joint is the part of our structure upon which most mechanical demands are placed and a large number of lesions are associated to it. These factors motivated the construction of a three-dimensional model of the human knee joint in order to simulate joint kinematics and obtain the mechanical demands on the main ligaments during knee flexion movements. METHODS: The finite elements method was used to build a three-dimensional, biomechanical model of the knee joint. In this model with six degrees of freedom, the flexion/extension movement is applied, while the other five degrees of freedom are governed by the interactions between joint components. RESULTS: Data was collected on the movements, on the internal/external and adduction/ abduction rotations, on the anterior/posterior, lateral/medial and upper/lower translations, and on the forces acting upon the four main joint ligaments, during a wide flexion/extension movement. These values were qualitatively compared with comparable values available in the literature. CONCLUSIONS: It was observed through an analysis of the results that several kinematic aspects are satisfactorily reproduced. The initial pre-load of the ligaments and the positioning of the ligament insertions in the model were shown to be relevant variables in the results.


Subject(s)
Humans , Finite Element Analysis , Knee Joint/anatomy & histology , Biomechanical Phenomena , Imaging, Three-Dimensional , Models, Anatomic , Knee/anatomy & histology , Knee/physiology , Numerical Analysis, Computer-Assisted
4.
Rev. bras. ortop ; 39(10): 601-607, out. 2004. ilus, tab
Article in Portuguese | LILACS | ID: lil-403001

ABSTRACT

A região superior do lábio da glenóide pode apresentar lesões labiais e tendinosas do bíceps braquial, sendo o conhecimento das variações anatômicas de grande importância para a realização de procedimentos artroscópicos. O objetivo do trabalho é determinar a origem labial do tendão da cabeça longa do bíceps braquial, comparando a visão macroscópica com a avaliação histológica. Foram realizadas dissecções de 36 ombros de 18 cadáveres conservados em formaldeído, no Laboratório de Ciências Morfológicas da Universidade Federal de Santa Catarina (LCM-UFSC). Foram avaliadas a estrutura macroscópica e a histológica da região do lábio superior, incluindo o local de origem labial do tendão da cabeça longa do bíceps braquial (CLB). A classificação anatômica utilizada foi a de Vangsness, que considera quatro tipos de origem labial da CLB. Foram feitos cortes histológicos seriados da região superior do lábio, com o objetivo de estudar a origem do tendão. Macroscopicamente, a principal origem labial da CLB foi na porção póstero-superior. A histologia mostrou que na maioria dos casos havia origem associada na porção ântero-superior. A avaliação macroscópica não é, portanto, confiável para determinar a origem labial do tendão da cabeça longa do bíceps braquial


Subject(s)
Humans , Male , Female , Cadaver , Shoulder
5.
ACM arq. catarin. med ; 30(1/2): 16-21, jan.-jun. 2001. tab, graf
Article in Portuguese | LILACS | ID: lil-452581

ABSTRACT

Vinte e quatro pacientes com diagnóstico de artrose tricompartimental e três com artrite reumatóide, foram submetidos à artroplastia total unilateral do joelho, utilizando prótese condilar total, com estabilizador posterior (Sistema Insall-Burstein), no Hospital Governador Celso Ramos, Aorianópolis, entre setembro de 1991 e setembro de 1997. Este estudo avaliou o resultado funcional de pacientes submetidos à artroplastia total do joelho. O tempo de seguimento pós-operatório foi de 14,9 meses, em média. Todos os pacientes referiram alívio do quadro doloroso; 78% foram capazes de caminhar .por 20 minutos ou mais no pós-operatório; 100% deles conseguiram caminhar mais de 300 metros e 81 % tiveram melhora da mobilidade articular. Com a colocação da prótese, as atitudes viciosas de flexão foram corrigidas em 87% dos casos e os pacientes tiveram menor dificuldade para subir escadas. Houve 2 casos de soltura asséptica dos componentes. Não houve nenhum caso de instabilidade articular no pós-operatório. Nos pacientes submetidos à artroplastia total do joelho houve diminuição da dor, aumento da distância e do tempo de caminhada, aumento da mobilidade articular e as complicações foram, na maioria das vezes, de pequena gravidade...


Subject(s)
Humans , Male , Female , Middle Aged , Aged, 80 and over , Arthroplasty, Replacement, Knee , Knee Prosthesis , Medical Records , Treatment Outcome
6.
Rev. bras. ortop ; 25(10): 373-6, out. 1990. tab
Article in Portuguese | LILACS | ID: lil-92501

ABSTRACT

Foi analisado o comportamento dos anéis do aparelho Ilizarov com 130, 160 e 200mm de diâmetro sob carga de compressäo, montado com fios de Kirschner de 1,5mm, com e sem tensäo, dobrados ou näo, e sobre três ou quatro apoios. Observou-se perda da estabilidade em anéis de maior diâmetro e em anéis sobre três apoios. O dobramento da extremidade dos fios näo melhorou a fixaçäo, mas permitiu identificar o início do escorregamento. Observou-se também comportamento diferente da fixaçäo dos fios nos parafusos com orifício central e fenda lateral


Subject(s)
Bone Lengthening/instrumentation , Bone Wires , Tensile Strength
7.
Rev. bras. ortop ; 25(6): 197-201, jun. 1990. ilus, tab
Article in Portuguese | LILACS | ID: lil-127383

ABSTRACT

Pelo estudo de 20 joelhos de cadáveres frescos determinou-se näo haver proporcionalidade entre as características mecânicas do ligamento cruzado anterior e do terço central do tendäo patelar. A resistência do ligamento cruzado anterior é proporcional ao tamanho do joelho e o mesmo näo acontece com a porçäo central do tendäo patelar. A resistência das estruturas estudadas näo se altera com a idade. Outros parâmetros foram estuddos e inter-relacionados


Subject(s)
Humans , Male , Female , Anterior Cruciate Ligament/physiology , Patellar Ligament/physiology , Biomechanical Phenomena , Regression Analysis
SELECTION OF CITATIONS
SEARCH DETAIL